Research on the HPLC Fingerprint Changes in Pre and Post-processed Pieces of Eucommia Ulmoides Oliv

平丽,杨中林,张丹,李萍
DOI: https://doi.org/10.3969/j.issn.1002-2392.2009.06.026
2009-01-01
Abstract:Objective:To study the HPLC fingerprint changes in pre-and post-processed pieces of Eucommia ulmoides Oliv.Methods:The HPLC fingerprint changes were studied.The analysis was performed on a SinoChrom ODS-BP analytical column(250mm×4.60mm,5μm)with acetonitrile and 0.1% phosphoric acid as mobile phases in gradient mode.The flow rate was 1.0mL·min-1,the detection wave length was 230nm,injection volume was 5μL,and the column temperature was 25℃.Results:the one pre-processed consists of 15 common peaks;the one processed by salt-water consists of 16 Peaks.Conclusion:Eucommiae ulmoides Oliv common peaks of its fingerprint increase and mostly peak areas descend after processed by salt-water.