Treatment of Organic-phosphoric Flame Retardants Wastewater by Aerobic Biochemical - Chemical Precipitation Process
Ai-jun TIAN,Bing LI,Shui WANG,Wei LIU,Xia-yin HUANG
DOI: https://doi.org/10.3969/j.issn.1674-4829.2012.01.012
IF: 11.4
2012-01-01
Environmental Science & Technology
Abstract:This paper introduces the practical application of aerobic biochemical-chemical precipitation technology in organic-phosphoric flame retardants effluent project,analyzes and summarizes the experience of engineering design and operation.It's shown by practice that after the treatment of aerobic biochemical-chemical precipitation technology,the average removal rate of COD,volatile phenol,TP,petroleum of effluent is 94.01%,99.93%,97.79%,91.08% respectively.The average concentration of COD,toluene,volatile phenol,TP,petroleum of effluent is 135,not detected,0.057,13.25,2.88 mg/L respectively.This technology has the advantages of stable operation and high treatment efficiency,which makes good social benefits to the enterprise.
What problem does this paper attempt to address?