Enhanced coagulation removal of organics during the pretreatment of power plant circulating cooling water
zhang yajun,ren xiangyun,xu ping,sun lihua
DOI: https://doi.org/10.1049/cp.2011.1245
2011-01-01
Abstract:When Beijing urban reclaimed water is used for power plant, reverse osmosis membrane is polluted seriously by organics which exist in circulating cooling water. Enhanced coagulation can effectively remove turbidity and reduce the reverse osmosis membrane organic pollution. In the experiment, polyaluminium chloride, polyaluminium ferric chloride, aluminium chloride, aluminum sulfate, ferric tri-chloride and ferrous sulfate are the experimental coagulants, and dosage, pH, hydraulic gradient and temperature are the changed factors. Results show that the six coagulants in their corresponding optimal conditions, the turbidity removal rate respectively achieved: 95.8%, 93.0%, 93.8%, 94.2%, 92.0% and 92.4%, and the COD Mn removal rate respectively achieved: 38.2%, 41.3%, 38.0%, 37.2%, 44.6 % and 37.2%. When pH of circulating cooling water is between 7 and 8, the six coagulants remove COD Mn performance order: ferric tri- chloride, polyaluminium ferric chloride, aluminium chloride, polyaluminium chloride, aluminum sulfate, and ferrous sulfate.