Abstract:The enhanced coagulation experiments have been carried on by combining bleaching agent dicyandiamide and PAC for treating the secondary effluent water in a printing & dyeing plant.The optimum composited ratio and coagulation conditions are determined.The results show that the best composited ratio of the coagulant is 0.12 mL/L of bleaching agent dicyandiamide and 87.5 mg/L of PAC.At this time,the decoloration rate is up to 74%,CODCr removing rate 57%,and UV254 removing rate 36%.The experimental results show that the composited coagulant is highly effective.