Performance tests of improved backheat-adsorptive-type prototype of air conditioner

Jin-ping LI,Ji YUAN,Lin-jun WANG,Ru-zhu WANG,Jing-yi WU,Yu-xiong XU
DOI: https://doi.org/10.3969/j.issn.1673-5196.2007.04.016
2007-01-01
Abstract:In order to investigate utilization performance of low-temperature exhausted heat of the improved backheat-adsorptive-type air conditioner prototype,the following system performances such as stability of heat sources,cooling water load,working conditions of absorber,temperature control of evaporator and prototype performance were analyzed through experiment in a cycle.It was found that the system parameters had good repetitability and symmetry about half cycle time,and the prototype had steady performance.When the heating temperature was 105 ℃,the refrigeration performance and refrigeration power of adsorbent of unit mass were 0.492 and 124 W/kg,respectively.Nevertheless,it would still be of great potential for the performance improvement of the prototype to enhance heat transfer and mass transfer in adsorbent beds.
What problem does this paper attempt to address?