Impact of Steam Distribution on Steam Turbine Safety and Optimization of Sequence Valve

Gao Sheng-hui,Wang Ying-xu,Yu Cun-xi,Liu Jin-fu
DOI: https://doi.org/10.3969/j.issn.1003-9171.2011.02.006
2011-01-01
Abstract:Irrational design of steam distribution nozzle will cause large steam distribution imbalance at governing stage, during load change of the generating unit,such imbalance leads to shaft system failures such as bearing axis offset,temperature rising and instable vibration,which is harmful to the safe operation of the unit.Based on the calculations under variable conditions at governing stage,this paper presents the mechanism and variation of flow imbalance during load changes and the root cause for flow imbalance is identified to be asymmetric inlet of steam.Actual operation data is applied to comprehensively analyze the adverse effects of distribution steam flow imbalance on the generating unit.Finally, based on optimization study of steam distribution,this paper put forward a steam distribution scheme that is combining diagonal steam admission at low load with sequence valve steam admission at high load.Practice proves that such optimization modification greatly improve the safety and economy of the unit.