Study on Treatment of Coking Wastewater by Biofilm Reactors Combined with Zero-Valent Iron Process.

Peng Lai,Hua-zhang Zhao,Ming Zeng,Jin-ren Ni
DOI: https://doi.org/10.1016/j.jhazmat.2008.06.034
IF: 13.6
2009-01-01
Journal of Hazardous Materials
Abstract:Experiments were conducted to investigate the behavior of the integrated system with biofilm reactors and zero-valent iron (ZVI) process for coking wastewater treatment. Particular attention was paid to the performance of the integrated system for removal of organic and inorganic nitrogen compounds. Maximal removal efficiencies of chemical oxygen demand (COD), ammonia nitrogen (NH3-N) and total inorganic nitrogen (TIN) were up to 96.1, 99.2 and 92.3%, respectively. Moreover, it was found that some phenolic compounds were effectively removed. The refractory organic compounds were primarily removed in ZVI process of the integrated system. These compounds, with molecular weights either ranged 10,000–30,000Da or 0–2000Da, were mainly the humic acid (HA) and hydrophilic (HyI) compounds. Oxidation–reduction and coagulation were the main removal mechanisms in ZVI process, which could enhance the biodegradability of the system effluent. Furthermore, the integrated system showed a rapid recovery performance against the sudden loading shock and remained high efficiencies for pollutants removal. Overall, the integrated system was proved feasible for coking wastewater treatment in practical applications.
What problem does this paper attempt to address?