EXPERIMENT STUDY OF CHLORONITROBENZENE ACTUAL WASTEWATER DECOLORIZATION BY OZONE TREATMENT TECHNIQUE

Xu Hengtao,Zhang Yi,Xu Xiangyang
DOI: https://doi.org/10.16796/j.cnki.1000-3770.2010.07.008
2010-01-01
Abstract:Based on the problem that chloronitrobenzene wastewater with deep color after second biochemical treatment,the performance of wastewater decolorization by ozone oxidation technology was studied in this paper,and the viability of industrial application was analyzed as well.The results indicated that the effluent decolorization rate could be improved by increasing ozone dosage and hydraulic retention time,and the ozone utilization efficiency was steady at 80%.Based on a model,it was found that the wastewater decolorization was related with the consumed ozone dose but not with applied ozone concentration and applied ozone dose.Comparing with other ozonized decolorization reactors,the upstream packed column reactor presented the best decolorization performance.At ozone dosage of 47.76 mg·L-1 and hydraulic retention time of 4 min,the operation cost for effluent decolorization was about 0.6~0.8 yuan·m-3 wastewater.