Abstract:Based on the fiber section analysis method and refined material constitutive model,a section analysis program for the composite shear walls with double steel plates and infill concrete was developed.The program was verified to be accurate by the available test results.From analysis of the calculated results of 6 379 composite shear walls with double steel plates and infill concrete,axial compression ratio,concrete strength,steel content ratio and confinement of concrete in the boundary columns were found to be the main factors that affect the deformability of composite shear walls with double steel plates and infill concrete.Research results show that simplified formulas for calculating the ultimate curvature obtained from the parameter study is accurate enough and on the safe side.On these basis,a displacement-based design approach for composite shear walls with double steel plates and infill concrete was proposed.For the Chinese design code,upper limit values for the axial compression ratio were provided: for concrete strength below C50,the upper limit value of the axial designed compression ratio was 0.45;for the concrete strength above C50,the upper limit value of the axial designed compression ratio can be calculated using formula n2d,lim=-0.004fcu+0.625.