Static Calibration of Geomagnetic Sensors for Attitude Measurement

LIU Jian-jing,ZHANG He,DING Li-bo
DOI: https://doi.org/10.3969/j.issn.1005-9830.2012.01.023
2012-01-01
Abstract:To eliminate the influence of the attitude angle measurement system of shells based on geomagnetic field resulting from the errors of 3-axis geomagnetic sensors,the static calibration technology is used to correct the errors.In terms of the sensitivity errors,bias errors and non-orthogonal errors of geomagnetic sensors,a calibration model is established.Methods for calculating the nine error coefficients of the model are deduced and a system is established to realize the static calibration of 3-axis geomagnetic sensors.Without the surrounding disturbance,the nine coefficients are obtained firstly,and then the calibration effect on the measurement system is evaluated by comparison.The experimental results indicate that the accuracy of the attitude angles measurement system increases one time after calibration and the calibration model can greatly decrease the errors of geomagnetic sensors.
What problem does this paper attempt to address?