Analysis on Energy Conservation of a New Type Hot- Air Drying System

杨宏军,樊栓狮,李静
DOI: https://doi.org/10.3969/j.issn.1002-6339.2009.06.002
2009-01-01
Abstract:A new type hot-air drying intergrated system of heat pump and rotary desiccant wheel(HDSHR) is proposed,and the system configration and its working principle are introduced.Thermodynamic analysis results show that on some working condition,HDSHR is more energy-efficient than both heat pump drying system(HPDS) and hot-air drying system of rotary desiccant wheel(HDSR).Using the specific moisture extraction rate(SMER) as performance index,R134a as the working fluid in refrigeration system,and when the maximum condensation temperature is 80℃ and the regeneration temperature of the LiBr rotary desiccant wheel is 70℃,we have determined the optimal working paremeters: the evaporation temperature of refrigeration system is 20℃ and the drying temperature of HDSHR ranges from 55℃ to 70℃.We have also calculated the SMER in its optimal drying temperature conditions,e.g.the SMER values of HDSHR ranges from 1.545 to 2.168 and that of HPDS ranges from 0.813 to 1.125.The results showed that HDSHR has a remarkable energy-efficient performance.
What problem does this paper attempt to address?