Determination of teicoplanin serum concentration in critically ill patients

HU Sa-sa,PANG Cheng-sen,DONG Hai-yan,DONG Ya-lin
2011-01-01
Abstract:OBJECTIVE To validate a high performance liquid chromatography(HPLC) method for serum teicoplanin measurement and using the method for clinical monitoring the levels of teicoplanin in critically ill patients.METHODS HPLC analysis was performed using a Hypersil C18 colum(250 mm×4.6 mm,5 μm).The mobile phase was NaH2PO4(0.01 mol·L-1):acetonitrile:methanol =70∶25∶5(pH 2.1).The flow-rate was 1.0 mL·min-1 and the detection wavelength was 240 nm.The injection volume was 20 μL and the temperature of column was about 25 ℃.RESULTS The concentration range of teicoplanin was 5.63~125.00 mg·L-1 while the calibration curve showed good linearity(r=0.999 5),and the minimum limit of quantitation was 5.63 mg·L-1.The coefficient of abstraction recovery and methods recovery were 95.13% and 98.13%,respectively.The relative standard deviations(RSD) of intra-day and inter-day were 3.2% and 6.8%,respectively.Moreover,the concentration of teicoplanin was lower than 10 mg·L-1 in fifty percent of those 8 patients with insufficient renal function.CONCLUSION This analytical method is simple,robust,rapid and highly reproducible,and it could be used in detecting the concentration of teicoplanin for critically ill patients.The concentration of teicoplanin has a large fluctuation in critically ill patients and their suitable individual dosage regimen need to be administrated through therapeutic drug monitoring.
What problem does this paper attempt to address?