A study for false level of the boiler steam-water system based on the (A)str(o)m-Bell model

Ting Ji,Lifang Zhou,Zhijiang Shao
DOI: https://doi.org/10.3969/j.issn.1001-4160.2012.09.003
2012-01-01
Abstract:The false water level in boiler drum under varying operating conditions affects the safety of the boiler seriously,thereby establishing a reproducible dynamic model for false water level analysis is necessary.This paper extends the nonlinear dynamic model put forward by Astrom and Bell in 2000,builds a simulation model in MATLAB/SIMULINK environment and conducts the open loop validation,finally analyses the property of false water level.It is verified that the change in steam flow rate,feed water flow rate and heat could cause the false water level,steam flow rate produce the most serious.Meanwhile,false water level varies at different load points of the same magnitude disturbance in steam flow,it is more serious in low-load point.
What problem does this paper attempt to address?