EFFECTS OF DELAYED FEEDBACK CONTROL ON VIBRATION SUPPRESSION IN AN AUTO-PARAMETRIC DYNAMICAL ABSORBER

Yanying Zhao,Jian Xu
DOI: https://doi.org/10.3969/j.issn.0254-7805.2007.04.004
2007-01-01
Acta Mechanica Solida Sinica
Abstract:The delayed feedback control is applied to suppress the vibration of the primary system in an auto-parametric vibration system.For the system subjected to the harmonic excitation,the method of multiple scales is employed to obtain the analytical solutions when the primary resonance and 1∶2 internal resonance occur simultaneously.Effects of gain and time delay on vibration suppression of the primary system are investigated.The results show that the vibration of the primary system can be suppressed at some values of the delay for a fixed gain.The "maximum vibration suppression point" is provided to suppress the vibration of the primary system maximally.We have concluded that the vibration of the primary system can be suppressed about 90% by comparing with the auto-parametric dynamical absorber.
What problem does this paper attempt to address?