Determination of hippuric acid in human urine by ion chromatography with conductivity detection.

Fuyong Zhao,Zonghua Wang,Hui Wang,Mingyu Ding
DOI: https://doi.org/10.1016/j.jchromb.2010.12.015
IF: 3.318
2011-01-01
Journal of Chromatography B
Abstract:A simple, rapid, precise and eco-friendly ion chromatography (IC) method for the determination of hippuric acid (HA) in human urine was proposed in this paper. The separation was carried out an anion exchange column with 2.0mmolL−1 Na2CO3+2.0mmolL−1 NaHCO3 as mobile phase at the flow-rate 0.7mLmin−1. A suppressed conductivity detector was used and the detection limit was 1.0μgL−1(S/N=3) for hippuric acid. The analysis time for one run was 30min under the optimized IC condition. The recovery of hippuric acid was 93.2–98.0% while the relative standard deviation (RSD) was 1.4–2.3% by seven measurements.
What problem does this paper attempt to address?