Combined freeze concentration and reverse osmosis technique for urine treatment in space station

YU Tao,MA Jun
DOI: https://doi.org/10.3969/j.issn.1672-0946.2007.03.011
2007-01-01
Abstract:Urine treatment is important to the close-looped Environmental Control and Life Support System in space station.Combines freeze concentration and reverse osmosis technique was put forward to treat urine in space station.Quality of the recovered water,energy consumption and water recovery ratio were evaluated by experimental investigation and theoretic analysis.The results show that the quality of the recycled water were: pH=6~8,electric conductivity <15 μs/cm,TOC<5 mg/L,NH3—N <0.5 mg/L,energy consumption to produce 1 kg pure water was less than 0.1 kWh,and the maximal water recovery ratio was 97.75%.The combined freeze concentration and reverse osmosis technique has potential in freating urine in space station and deserves farther research.
What problem does this paper attempt to address?