[Characterization and Biocompatibility of Human-Like Collagen-Hyaluronic Acid Scaffold for Blood Vessel].

Xiujuan Sun,Daidi Fan,Chenhui Zhu,Xiaoxuan Ma,Yane Luo,Lan Chen,Jiaqing Guo
DOI: https://doi.org/10.3321/j.issn:1000-3061.2009.04.019
2009-01-01
Abstract:Human-like collagen (HLC) was cross-linked with hyaluronic acid by genipin in different ratio. The concentrations of hyaluronic acid in the mixture were 0, 0.01%, 0.05% and 0.1%. The blood vessel tubular grafts were then fabricated by freeze-drying. Microstructure, element composite, mechanical properties, cytotoxicity grade, and biocompatibility of different vascular scaffold groups were studied by scanning electron microscope (SEM), X-ray photoelectron spectroscopy (XPS), tensile test, burst pressure experiment, cytotoxicity experiment, endothelial cells planted in blood vessel scaffolds and hypodermic embedding of mice. The results showed that HLC-HA (0.05%) tubular scaffold exhibited interconnected well-distributed and porous structure and porosity of 94.38%; achieved the desirable mechanical property with stress of (1000.8 +/- 7.9) kPa and burst pressure of (1058.6 +/- 8.2) kPa, hypocytotoxicity, favourable cytocompatibility, hisocompatibility and disposition of degradation.
What problem does this paper attempt to address?