Studying a kind of portable ultra-bright microfocus x-ray source

Wang Kai-Ge,Wang Lei,Niu Han-Ben,王凯歌,王雷,牛憨笨
DOI: https://doi.org/10.1088/1674-1056/18/5/015
2009-01-01
Chinese Physics B
Abstract:This paper studies the properties of a kind of portable ultra-bright microfocus x-ray source with the Monte-Carlo method in detail.The new x-ray source consists of an electron-emission system,an electrostatic focusing system and a metal target.A crystal Lanthanum Hexaboride cathode,a Wehnelt grid and an extracted electrode compose the triode electrode electron-gun system.Two equal radius cylinder electrodes form the focusing system.The key factors determining the focus properties of the electron beam such as the ratio D_w/H,grid bias V_g,and the properties of the extracted electrode are numerically studied.The calculated results reveal that when D_w/H,V_g,the length of the extracted electrode,and the distance between the grid and the extracted electrode equals 5,-0.6 kV,10 mm,and 8 mm respectively,the electron beam focal spot can be concentrated down to 9μm in radius and a reasonable focal length about 72.5 mm can be achieved,at the same time,the cathode emission currents can be as high as 30 mA.