Abstract:For some operating conditions,a synchronous generator with a rectifier and back-EMF load maybe exhibit low-frequency oscillations when the system parameters do not match.To eliminate the low-frequency oscillations, a stability criterion for small disturbances was derived using the Routh criteria based on the characteristic system equation with the characteristic roots and equivalent impedances of the system calculated and analyzed.The lowfrequency oscillations of the system were due to the negative equivalent system impedance which results in self-excitation and Hopf bifurcation.The low-frequency oscillations occur when the equivalent system impedance is zero and an imaginary conjugate pair of eigenvalues appears.Simulations verified the theoretical analysis.Several measures are given to eliminate the oscillations such as installing a shortcircuited quadrature-axis winding on the rotor and increasing the quadrature-axis damper winding time constant.