Experimental study of low-frequency ultrasound combined with microbubbles on the expression of vascular endothelial growth factor in prostate cancer DU145 cells

SHEN E,HU Bing
DOI: https://doi.org/10.3877/cma.j.issn.1672-6448.2013.12.016
2013-01-01
Abstract:Objective To explore the influence of low-frequency ultrasound combined with microbubbles on expression of vascular endothelial growth factor(VEGF) in the prostate cancer DU145 cell line. Methods Cultured prostate cancer DU145 cells at logarithmic growth phase were used for experiment. The cells were randomly divided into four groups: control(1 ml cell suspension), microbubbles(800 μl cell suspension plus 200 μl microbubble contrast agents SonoVue), low-frequency ultrasound(1 ml cell suspension irradiated with 80 kHz ultrasound frequency, 0.45 W/cm2ultrasound intensity for 30 seconds), low-frequency ultrasound combined with microbubbles(800 μl cell suspension and 200 μl SonoVue irradiated with 80 kHz ultrasound frequency,0.45 W/cm2ultrasound intensity for 30 seconds). MTT test was used to detect the cell viability. Cell apoptosis was analyzed by flow cytometry. Western blot was applied to determine the expression level of VEGF protein. Statistical significances of cell viability, apoptosis and the level of VEGF expression were determined by one-way ANOVA followed by Student-Newman-Keuls-q for the comparison between two groups. Results The percentages of cell viability were 100%,(96.50±12.49)%,(93.20±5.31)%,(81.30±9.32)% in groups control, microbubbles, low-frequency ultrasound and low-frequency ultrasound combined with microbubbles, respectively. The cell apoptosis rate was(1.10±0.26)%,(1.78±0.63)%,(5.85±0.45)%,(9.36±0.90)%, respectively. The levels of VEGF protein expression were(0.81±0.05),(0.79±0.06),(0.58±0.04),(0.38±0.05), respectively. Compared to control, cell viability had no statistically significant difference in microbubbles and low-frequency ultrasound groups. The cell viability in lowfrequency ultrasound combined with microbubbles group was lower than control group, and the difference was statistically significant(q=5.88, P < 0.05). Cell apoptosis rate and the level of VEGF protein expression in microbubbles group had no statistical significance compared with control group. The apoptosis rate in low-frequency ultrasound group and low-frequency ultrasound combined with microbubbles group were higher than control group while the levels of VEGF protein expression were lower, and the differences were statistically significant(q=14.09, 24.51, 8.06, 14.89, all P < 0.05). Compared with low-frequency ultrasound group, the apoptosis rate in low-frequency ultrasound combined with microbubbles group was higher whereas the level of VEGF protein expression was lower, and the differences were statistically significant(q=10.42, 6.83, both P < 0.05). Conclusion Microbubbles can enhance the effect of low-frequency ultrasound in inhibiting cell viability and inducing apoptosis, the mechanism may be associated with the down-regulation of VEGF expression of prostate cancer DU145 cells.
What problem does this paper attempt to address?