Analysis of factors affecting suction volumetric efficiency of large caliber piston pumps

GUO Guangming,ZHANG Xiaolan,DONG Yulu,WU Miao
DOI: https://doi.org/10.16816/j.cnki.ksjx.2010.23.022
2010-01-01
Abstract:The suction volumetric efficiency is the comprehensive technical index of the pumping performance of the large caliber piston pump. It is not only related to the operation efficiency,but also affects the calculation of the conveyance flow in pipelines. A self-developed pump suction volumetric efficiency testing device was applied to test the suction properties of the piston pump used for coal slime,paper sludge and calcium carbide mud with taking mass fraction,suction velocity and slenderness ratio of hydraulic cylinder as major affecting factors. The results show that the suction volumetric efficiency decreases gradually with the increase in mass fraction. When the suction velocity of the suction cylinder is less than or equals to 0.23m/s,the suction volumetric efficiency increases with the increase in suction velocity. With the changes of the slenderness ratio of suction cylinder,the suction volumetric efficiency almost remains unchanged. The above results provide test data for structural optimization of the large caliber piston pump and experimental research on pumping characteristics.
What problem does this paper attempt to address?