The Minimum Rotor Rotation Angle for Calculating On-load Electromotive Force Waveform of Synchronous Generators

XIA Yonghong,WANG Shanming,HUANG Shaogang,QIU Arui
DOI: https://doi.org/10.13334/j.0258-8013.pcsee.2012.30.017
2012-01-01
Abstract:For quickly calculating the steady state performance of synchronous generators in on-load operating conditions,it hopes that the electromotive force(EMF) waveforms of the armature windings are calculated accurately when the rotor rotation angle is small as soon as possible.According to theories of electric machines,air-gap flux density of synchronous generator with fractional slot winding in on-load operating conditions was analyzed,and the minimum rotor rotation angle of accurately calculating the EMF waveforms of the armature windings was obtained.Electromagnetic fields was calculated for different rotor positions within the minimum rotation angle based on the finite element method,and each stator tooth flux waveform in one or more cycles was gotten,so that the EMF waveforms of the armature windings was calculated quickly.On-load EMF waveforms of two permanent magnet synchronous generators with different armature windings are calculated,and the comparisons of the calculated results verify the correctness of the method.Experiments are performed on an electric machine,and the comparison of calculated and experimental results verify the accuracy of the method.Therefore,this method has the advantages of accuracy and low time consuming.