Assessment of Portal Vein System with Contrast-enhanced Ultrasound in the Liver Transplant Candidates

Ren Jie,Zheng Rongqin,Yan Ping
DOI: https://doi.org/10.3969/j.issn.1002-0101.2007.01.016
2007-01-01
Abstract:Objective To assess the difference between 2-D ultrasound(B-US) and contrast-enhanced ultrasound(CEUS) in evaluating portal vein system in the liver transplant candidates.Methods A total of 32 patients suspected with portal vein thrombosis(PVT) were examined using CEUS.Results Twenty patients with PVT and 6 patients with normal PV were confirmed by liver transplant surgery,MR portograghy or spiral CT portography.The diagnostic confidence of B-US and CEUS was 8.26±1.98 and 9.38±0.95,respectively;②Sensitivities,specificities,and accuracies of B-US and CEUS were 88.2%,33.3% and 69.2% vs 82.4%,100% and 88.5%,respectively;③PVT was discovered in 14 cases(14/14,100%)on CEUS which could distinguish benign and malignant PVT,complete and incomplete embolism in all the cases; but only 8/15(53.3%) cases could be distinguished on B-US.Conclusions CEUS can not only improve diagnostic level of PVT but also provide more information.