Independent Interfraction Motion And Deformation Of Pelvic Nodes And Prostate In Image Guided Concurrent Irradiation Of Prostate And Pelvic Nodes

A.D. Currey,E. Ahunbay,C. Peng,Y. Chang,C.A. Lawton,X. Li
DOI: https://doi.org/10.1016/j.ijrobp.2008.06.873
2008-01-01
Abstract:In image-guided concurrent treatment of the prostate and pelvic lymph nodes (PLN), patients are often repositioned based on the daily prostate location. However, the PLN may move/deform independently with respect to the prostate. The repositioning may result in dosimetric consequence to PLN. The purpose of this work is to characterize the independent interfraction motion and deformation of the prostate and PLN and to investigate the impact of the repositioning on the PLN dosimetry. Daily kVCT images for 6 prostate cancer patients treated with CT-guided repositioning using a linac and CT-on-Rails combo (CTVision, Siemens) were analyzed. IMRT was used to treat the prostate and PLN concurrently. The prostate and PLN were defined on 9-10 scans per patient, chosen at random from the daily CT data set (total 59 scans). PLN were defined as outlined in the RTOG nodal atlas. While every effort was made to ensure accurate structure delineation, some inconsistency could not be eliminated. The daily prostate and PLN contours were compared to the planning contours after bony anatomy registration. Several quantities, including distance between center of mass (DCOM), Dice's coefficient (DC), maximum overlapping rate (MOR), were measured for each structure and were used to characterize the prostate and PLN motion and deformation. To study the dosimetric impact, the delivered 3D dose distribution for each treatment fraction was reconstructed by placing beams/segments on the CT of the day after the repositioning based on manual prostate alignment. The dose coverage of the PLN for each fraction was measured by DVH, D90 (dose to 90% of PLN volume) and V100 (percentage volume covered by 100% of prescribed dose). Mean DC for prostate and PLN was 72.0 ± 8.8% and 65.4 ± 9.2%, and mean DCOM was 4.5 ± 2.2 mm and 7.8 ± 3.5 mm. This difference caused reduction in dosimetric coverage of PLN even when a 1.0 cm PTV margin is added. On average, D90 drops 5% and 12%, before and after the repositioning shift (SD = 9% and 16% with p < 0.0005). The median PLN V100 decreases 2% and 11% before and after the shift. Patient variation was large (SD of mean = 10.8%). The magnitude of PLN underdosing increased with shifts (R = 0.5), showing that PLN are relatively stationary compared to the prostate. For some cases, there was large underdosing (D90 >10%) of the PLN even before the shifts. This is due mostly to the PLN deformation and contouring inconsistency. The pelvic lymph nodes move and deform independently from the prostate. In the concurrent treatment of the prostate and PLN, the current IGRT practice of patient repositioning based on the prostate alignment can lead to negative impact on the PLN dosimetry if the margin for PLN is not appropriate.
What problem does this paper attempt to address?