CFD Numerical Simulation of the Internal Flow Field of the Vertical Pipe of the Texaco Coal Gasifier

Li Gangjian,Yang Lei,Yang Hongbo,Luo Chuntao,Chen Xueli
DOI: https://doi.org/10.3969/j.issn.1005-9598.2012.06.015
2012-01-01
Abstract:The parameters as well as the operation philosophy of the vertical pipe of the Texaco coal gasifier were discussed.By using the CFD software,the cold-state simulation of the gas flow distribution of the vertical pipe under normal operation conditions was performed,and performed also was the simulation under such abnormal conditions as partial plugging,symmetrical plugging,non-symmetrical plugging at the slag discharge end.The result showed that plugging at the slag discharge end causes bias gas flow in the vertical pipe.
What problem does this paper attempt to address?