Highly Selective Iodide Electrode Based on the Copper(II)- N , N ′-bis(salicylidene)-1,2-bis( p -aminophenoxy)ethane Tetradentate Complex

Wen-Ju Xu,Ya-Qin Chai,Ruo Yuan,Lan Xu,Su-Li Liu
DOI: https://doi.org/10.2116/analsci.22.1345
IF: 1.967
2006-01-01
Analytical Sciences
Abstract:In this paper, a new PVC-based liquid-membrane anion-selective electrode based on a copper(II) of N , N ′-bis(salicylidene)-1,2-bis( p -aminophenoxy)ethane tetradentate complex (Cu(II)BBAP) is described, which displays a preferential potentiometric response to iodide ion at pH 2.0 and an anti-Hofmeister selectivity sequence: I – > SCN – > ClO 4 – > NO 2 – > H 2 PO 4 – > NO 3 – > SO 4 2– > Br – > Cl – . The electrode exhibits a near-Nernstian potential linear range of 8.2 × 10 –7 –1.0 × 10 –1 M with a detection limit of 5.3 × 10 –7 M and a slope of–58.8 mV per decade. The A.C. impedance technique and the UV/Vis spectroscopy technique were used to analyze the response mechanism. The electrode could be applied to determine iodide in medicine analysis, and the obtained results were fairly satisfactory.
What problem does this paper attempt to address?