The XTT Colorimetric Assay Measuring the Cell Growth Curve

WU Nan,CUI Heng,WEN Kai-hui,HU Chun-yan,LI Ping
DOI: https://doi.org/10.3969/j.issn.2095-140x.2007.04.003
2007-01-01
Abstract:Objective:To investigate the feasibility of XTT colorimetric assay as a method for cell growth curves.Methods:The XTT colorimetric assay was used as a method for cell growth curves of ovarian carcinoma cell lines 3AO and was compared with the MTT assay.Results:The cell growth curve of 3AO obtained by the XTT colorimetric assay was not only similar to the MTT assay,but also more rapid and simpler than MTT.Conclusion:XTT colorimetric assay can replace MTT assay to measure the cell growth curve and is better than MTT.
What problem does this paper attempt to address?