The Application of the Homemade 11C-Module in the 11C Labeling Radiopharmaceuticals

张政伟,薛方平,刘平,石斌,王慧春,管一晖
DOI: https://doi.org/10.3969/j.issn.1674-1633.2009.08.002
2009-01-01
Abstract:Objective The use of [11C]-labelled radiopharmaceuticals such as 11C-acetate,11C-choline,11C-methionine and 11C-PIB had been proven useful in providing incremental values to the clinical diagnosis.For the routine use,a fully automated module adopting a LOOP method instead of reaction vessel synthesis has been developed.Methods The module was completed by modifying the current module for the 11C-holine and 11C-acetate,11C-choline,11C-methionine and 11C-PIB.The above [11C]-labelled radiopharmaceuticals were synthesized.Results The [11C]-labelled radiopharmaceuticals had high radiochemical purity(≥95%) and moderate radiochemical yields(only 10% for the 11C-PIB,40%-55% for others).Conclusion LOOP method was a fast,versatile,and reliable method for the synthesis of 11C-acetate,11C-choline,11C-methionine and 11C-PIB in the routine use.
What problem does this paper attempt to address?