The Clinical Application of Color, Doppler Energy in Predicting Pregnancy Outcome During Frozen Thawed Embryos Transfer Cycles

L. Wang,J. Qiao,R. Li,X. Zhen
DOI: https://doi.org/10.1016/j.fertnstert.2007.07.560
IF: 6.7
2007-01-01
Fertility and Sterility
Abstract:To discuss the application of blood flow screening in endometrium by color Doppler energy (CDE) in the prediction of FET outcomes. Prospective study. 248 women were recruited in this prospective study. Endometrial thickness, echo pattern and blood flow status were detected by transvaginal ultrasonography one day before FET. The patients were divided into three groups: Group A, none or less endometrial blood flow could be detected; Group B, only sub-endometrial blood flow could be detected and Group C, both the endometrial and sub-endometrial blood flow could be detected. Then all the patients were re-divided into three groups according to their outcomes: Group 1, no pregnancy; Group 2, intrauterine pregnancy with live fetus; Group 3, others (include biochemical pregnancy, embryonic diapause, ectopic pregnancy and abortion). The pregnancy rate was 45.56%, and the implantation rate was 17.70% in these FET patients. The clinical pregnancy rate with live fetus was 69.02% in Group C, much higher than that in Group A and B (7.08% and 16.81%), P≤0.001. The implantation rate in Group C was 53.9%, significantly higher than that in Group A and B which were 12.5% and 20.88% respectively, P<0.001. The implantation rate should the same rate as 53.9% vs. 12.5%, 20.88% in Group C than that in Group A and B, P≤0.001. Endometrium S/D, PI and RI were 2.42 ± 0.43, 0.93 ± 0.17 and 0.57 ± 0.07 in the group 3, much lower than that in Group 1 and Group 3, P1–2<0.001, P2–3<0.001. Area Under the Curve of pulsatility index, resistive index, and S/D of endometrial spiral arteries were 0.816, 0.801 and 0.818. Neither endometrial thickness, echo pattern, endometrial volume nor blood flow of uterus artery and ovary artery showed significant difference among Group 1, 2, and 3. The status of endometrial blood flow one day before FET was closely associated with FET outcomes. Those whose endometrial blood flow could be detected showed higher clinical pregnancy rate and implantation rate. The clinical application of CDE in checking the endometrial blood flow was a non-invasive and very effective method in predicting a positive pregnancy outcome, it may be widely used for routine FET cycles.
What problem does this paper attempt to address?