HPLC Determination of Scutellarin and Its Related Substances in Breviscapine Injection

ZHENG Jin-feng,LI Wen-li,FENG Fang
DOI: https://doi.org/10.16155/j.0254-1793.2011.01.016
2011-01-01
Abstract:Objective:To establish an RP-HPLC method for the determination of breviscapine injection and its related substances.Methods:In this HPLC method,Agilent TC C18(5 μm,4.6 mm×250 mm) column was adopted,the mobile phase consisted of methanol-0.1 mol·L-1 ammonium acetate(adjusted to pH 3.0 with phosphoric acid)(32∶68) at the flow rate of 1.0 mL·min-1 with the detection wavelength of 335 nm.Results:The prominent peak and the neighbor subsidiary peak could be completely separated by the methed.The standard curve was linear in the range of 26.02-312.24 μg·mL-1(r=0.9994,n=5),with the detection limit of 2 ng.The prominent related substance was 4′-hydroxybaicalein-7-O-β-D-pyrangluconatemethyleste.Conclusion:The method is proved to be selective,accurate and suitable for the quality control of breviscapine injection.
What problem does this paper attempt to address?