Removal of soluble manganese from drinking water with various oxidant
Yu-chao TANG,Man-tian XU,Yan-yan YANG,Wei SHI,Xian-huai HUANG,Wei HU,Wei-hua LI,Yi-qun QIAN
DOI: https://doi.org/10.16581/j.cnki.issn1671-3206.2017.11.019
2017-01-01
Abstract:The effects of dosages of oxidant which were available in water treatment (KMnO 4 ,ClO NaClO,Na 2 S2 O8 ,KHSO 5 and ozone),multi-oxidants,UV light,pH value and coexist ions were investiga-ted. The results showed that the KMnO4 and O3 were effective oxidants for the removal of Mn2 +,when the molar ratio of KMnO4 and Mn2 + was 2: 3,after 30 min,the residual manganese was 0. 006 mg,5 min later Mn2 + decrease to 0. 056 mg / L under 0. 6 L/ min O3 air flow rate. The performance of the removal can be best improved when KMnO4 or O3 were used under high pH;ClO 2 performed a certain effect;Under UV light,in UV 254 / ClO2 ,UV 254 / KHSO5 and UV254 / Na2 S2 O8 system,the molar ratio of oxidants and Mn2 +were 8: 5,4: 1 and 4: 1,the Mn2 + concentration was 0. 8 ~ 0. 9 mg / L simulated water sample,the residual manganese decreased to 0. 006,0. 006,0. 001 mg / L respectively,these were better than the national standard. NaClO were not effective oxidants for Mn2 + removal in a short time,but UV 254 / NaClO performed a certain effect. The molar ratio of KHSO5 / KMnO4 and Mn2 + were 5: 2,Mn2 + decreased to 0. 06 mg / L, the performance can be highly improved than used separately.