A new absorbable synthetic elastomer used in retinal detachment surgery for absorbable implants

邱庆华,曾水清,柯天一,吴颖楠,王方
DOI: https://doi.org/10.3760/cma.j.issn.1008-1801.2005.04.016
2005-01-01
Abstract:Objective To find new absorbable synthetic materials that can be used in retinal detachment surgery.In detachment surgery,a mechanically stable chorioretinal scar with full scleral indentation is no longer necessary.Under these considerations,absorbable scleral implants have been developed and tested in an animal model.Methods Phosphate-carbonate copolymer was synthesized by polytetrahydrofuran and bisphenol A.Rhegmatogenous retinal detachments were created in 20 rabbits,which then underwent scleral buckling procedures with phosphate-carbonate copolymer implants.The rabbits received an injection of hyaluron and a break was created with a 7G needle.A localized retinal detachment was induced by a subretinal injection of liquefied vitreous using a transvitreous approach.The crystalline lens was not removed.The follow-up period was for 1 and 2 weeks and 1,2,3,4,5 and 6 months.Pieces of absorbable material with a diameter of 7~8 mm were sutured as scleral explants in 20 rabbits.Buckle height after the operation was measured with B-scan ultrasonography and the eyes were enucleated for histopathological examination at regular intervals.The degradation of phosphate-carbonate copolymer in vivo was investigated in another 10 rabbits.Results B-scan ultrasonography showed that the initial explants had buckle heights between 2.7 mm and 3.5 mm.A clinical and ultrasonographical follow-up study showed a continuous slow decrease in buckle height.Ultrasonography measurements of the explants showed buckle heights between 2.7 mm and 3.2 mm at the end of 3 months,and between 2.0 mm and 2.7 mm at the end of 6 months.Histopathological examinations showed an incidence of a slight resorptive inflammation in the area of the buckle,which was not evident after 4 weeks.No scleral infiltration or scleral thinning was found.The retina was successfully attached in all rabbits without any local complications.The amount of postsurgical buckle height was almost unchanged during the initial 3 months.The phosphate-carbonate copolymer implant had an 8.2% absorption rate at the end of 3 months and 11.4% at the end of 4 months.Conclusion These promising results justify controlled clinical trials with the absorbable material,which would combine the advantages of silicone sponge explants(precise localization) with those of scleral buckles from inflatable balloons(reversibility).The absorbable implants were well tolerated in all eyes.Phosphate-carbonate copolymer lasted sufficiently long and produced a significant buckling effect for at least 6 months.We consider this type of explant to be the ideal material for retinal detachment healing because it has a longer reabsorption period compared to other explants,allowing for a longer indentation period.Phosphate-carbonate copolymer was effective and safe in the treatment of retinal detachment.
What problem does this paper attempt to address?