Application of CAD/CAM technique in the reconstruction of the orbital fracture associated with eyeball rupture

ZHANG Zhiyong,HE Yang,ZHANG Yi
DOI: https://doi.org/10.3969/j.issn.1001-3733.2011.01.08
2011-01-01
Abstract:Objective:To analyse the character of the orbital fractures associated with eyeball rupture and evaluate the application of the CAD/CAM technique in the orbital reconstruction.Methods:8 patients with orbital fracture accompanying eyeball rupture were treated.CT scan was taken for all the patients preoperatively and postoperatively.Surgical simulation was performed based on the CT data under the help of software.The pre-bent titanium mesh was manufactured and grafted to the traumatic orbital walls.Results:Based on the analysis of the preoperative CT scanning,the defect of the orbital wall and the herniation of the orbital soft tissue were serious in all the cases.Most of the fractures were impure.The orbital reconstruction was satisfactory in all the patients according to the postoperative CT data and no serious complication was found.The volume of the herniated soft tissue was reduced from 3.8 ml to 1.1 ml and the postoperative degree of enophthalmos was less than 3 mm in 7 of the 8 cases.Conclusion:The herniation of the orbital soft tissue and the traumatic degree are serious in the orbital fracture associated with eyeball rupture.The pre-bent titanium mesh is effective in the orbital reconstruction.
What problem does this paper attempt to address?