Direct Separation and Quantitative Determination of Glimepiride Isomers by High Performance Liquid Chromatography
Y Song,LP Niu,DF Wang,YP Hu,DY Hou
DOI: https://doi.org/10.1002/jssc.200301508
IF: 3.614
2003-01-01
Journal of Separation Science
Abstract:A simple and sensitive high-performance liquid chromatographic procedure for the determination of the trans isomer of glimepiride is reported. Chromatography accomplished direct separation of the cis and trans isomers of glimepiride on a Dikmonsil C18 (250 x 4.6 mm, 5 mum) column with a mobile phase consisting of methanol-acetonitrile-NH4Ac buffer solution (1.5 mol L-1, pH = 4.5) (1.1 : 1.3 : 1.0, v/v) at a flow rate 0.5 mL min(-1). The resolution (R-S) was 1.73 with a retention time of 24.885 and 23.018 min for the cis and the trans isomer, respectively. A standard linear calibration curve was established for the trans isomer of glimepiride over the range of 4.95-198.00 mug mL(-1) with a correlation coefficient of 0.99997. This method has been successfully used to analyze four different kinds of glimepiride product.
What problem does this paper attempt to address?