Application of Multifocal Visual Evoked Potential in the Diagnosis of Primary Glaucoma

杨新光,刘钊,于敬妮,刘建荣,潘爱珠
DOI: https://doi.org/10.3760/cma.j.issn.1674-845x.2009.01.013
2009-01-01
Abstract:Objective To compare the difference in multifocal visual evoked potential(mVEP) between glaucoma patients and normal persons,to evaluate the value of mVEP in the diagnosis of primary glaucoma.Methods Forty-nine glaucoma patients and 30 normal persons agreed to participate in the mVEP testing.One eye from each individual was included in the study to analyze the signal-to-noise ratio(SNR) and latencies using a student t-test.One eye was randomly selected from each normal participant.In the glaucoma group,if both eyes showed glaucomatous optic neuropathy,then the eye with the lesser field defect was included in the study.If only one eye satisfied the glaucoma inclusion criteria,then it alone was included in the study.Results The latencies of the glaucoma patients [(108.40±15.29)ms] were significantly longer compared to the latencies of the normal participants [(97.84 ±8.22) ms](P0.01).The SNR of glaucoma patients(2.19±0.74) was significantly decreased compared to the SNR of normal individuals(2.63± 0.59)(P0.01).There was a significant positive correlation between the SNR and mean deviation(MD) of the visual field(r=0.64,P 0.05),and a negative correlation between the latencies and MD(r =-0.47,P 0.05).Conclusion The mVEP of glaucoma patients can reflect visual function damage more objectively within different regions of the visual field.SNR is better than latencies in the evaluation of mVEP.
What problem does this paper attempt to address?