Bioequivalence of Cefalexin in Healthy Chinese Subjects
Xiaozhi Lv,Guoping Zhong,Herui Yao,Junyan Wu,Suiwen Ye
DOI: https://doi.org/10.5414/cp203986
2021-01-01
International Journal of Clinical Pharmacology and Therapeutics
Abstract:Objective: An earlier three-way crossover study evaluating bioequivalence of 3 cefalexin formulations (capsule for reference, capsule and tablet for test) in healthy subjects in Malaysia showed that the intra-individual coefficients of variation were 9.25% for AUC(0-t), 9.54% for AUC(0-8), and 13.90% for C-max. It is preliminarily stated that cefalexin is not a high-variation product. The here-presented clinical study in China was carried out to analyze the pharmacokinetic properties of two preparations in fasting and postprandial condition to assess the bioequivalence of the test preparation and reference preparation when administered on a fasting and postprandial basis in healthy Chinese subjects and to observe the safety of the test preparation and reference preparation in healthy Chinese subjects. Materials and methods: In this trial, a total of 56 eligible subjects were randomly assigned to the fasting group and the postprandial group. The two groups were given 250 mg of the test and reference preparation, respectively. Liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was applied to determine the plasma concentration of cefalexin. PhoenixWinNonlin software (V7.0) was used to calculate the pharmacokinetic parameters of cefalexin using the non-compartmental model (NCA), and the bioequivalence and safety results were calculated by SAS (V9.4) software. Results: The main pharmacokinetic parameters of the test and reference preparations were as follows, the fasting group: C-max 12.59 +/- 2.65 mu g/mL, 12.72 +/- 2.28 mu g/mL; AUC(0-8h) 20.43 +/- 3.47 hx mu g/mL, 20.66 +/- 3.38 hx mu g/mL; AUC(0-8) 20.77 +/- 3.53 hx mu g/mL, 21.02 +/- 3.45 hx mu g/mL; the postprandial group: Cmax 5.25 +/- 0.94 mu g/mL, 5.23 +/- 0.80 mu g/mL; AUC(0-10h) 16.92 +/- 2.03 hx mu g/mL, 17.09 +/- 2.31 hx mu g/mL; AUC(0-8) 17.33 +/- 2.09 hx mu g/mL, 17.67 +/- 2.45 hx mu g/mL. Conclusion: The 90% confidence intervals of geometric mean ratios of test preparation and reference preparation were calculated, and the 90% confidence intervals of geometric mean ratios of Cmax, AUC(0-10h), and AUC(0-8) were within the 80.00% similar to 125.00% range in both groups. Both Cmax and AUC met the pre-determined criteria for assuming bioequivalence. The test and reference products were bioequivalent after administration under fasting as well as under fed conditions in healthy Chinese subjects. This study may suggest that successful generic versions of cefalexin not only guarantee the market supply of such drugs but can also improve the safety and effectiveness and quality controllability of cefalexin through a new process and a new drug composition ratio.