Study on the Damage of Peripheral Nerve in the Workers Exposed to N-Hexane

杨锦蓉,张幸,王菁,钱亚玲,吴志英,汪严华,庞孟涛
DOI: https://doi.org/10.3969/j.issn.1000-6486.2007.06.008
2007-01-01
Abstract:Objective To study the damage of peripheral nerves in the workers exposed to n-hexane.Methods An occupational health survey in a shoemaking corporation was carried out,covering 206 n-hexane exposed workers and 128 controls.Questionnaire,health inspections,nerve electromyogram(EMG),urine 2,5-hexanedione and serum neuron specific enolase(NSE)were examined.Results n-Hexane concentration in "up lasting" workshop exceeded the national exposure limit,the workers there having debilitation,body anaesthesia,difficulty in walking,crouching and standing,weakness in lower limbs,span gait,myodynamia decrease,superficial sensation decrease and tendon reflex decrease.The above indexes had significant differences with those found in the "down lasting" workshop and the controls(P0.01).The results showed that 69.1%(172/249)of the motor nerves had slow conduction velocity,24.9%(62/249)had amplitude descent,12.9%(32/249)had delayed distal latency and 75.8%(141/186)of the sensory nerves had slow velocity.2,5-Hexanedione was detected in the exposers' urine and the abnormality rate of serum NSE level was 22.6%.Conclusion Nerve system,nerve conduction velocity and level of 2,5-hexanedione and serum NSE of the workers may be affected by n-hexane that exceeds the occupational exposure limit in the workshop.
What problem does this paper attempt to address?