Turbulent Convection Mass Transfer of Water with Internal Mass Sources

Pei-Xue Jiang,V.S. Protopopov,Ze-Pei Ren,Bu-Xuan Wang
DOI: https://doi.org/10.1002/(sici)1523-1496(200005)29:3<166::aid-htj2>3.0.co;2-m
2000-01-01
Abstract:Heat Transfer—Asian ResearchVolume 29, Issue 3 p. 166-180 Turbulent convection mass transfer of water with internal mass sources Pei-Xue Jiang, Pei-Xue Jiang Tsinghua University, ChinaSearch for more papers by this authorV.S. Protopopov, V.S. Protopopov Moscow Power Institute, RussiaSearch for more papers by this authorZe-Pei Ren, Ze-Pei Ren Tsinghua University, ChinaSearch for more papers by this authorBu-Xuan Wang, Bu-Xuan Wang Tsinghua University, ChinaSearch for more papers by this author Pei-Xue Jiang, Pei-Xue Jiang Tsinghua University, ChinaSearch for more papers by this authorV.S. Protopopov, V.S. Protopopov Moscow Power Institute, RussiaSearch for more papers by this authorZe-Pei Ren, Ze-Pei Ren Tsinghua University, ChinaSearch for more papers by this authorBu-Xuan Wang, Bu-Xuan Wang Tsinghua University, ChinaSearch for more papers by this author First published: 30 March 2000 https://doi.org/10.1002/(SICI)1523-1496(200005)29:3<166::AID-HTJ2>3.0.CO;2-MAboutPDF ToolsRequest permissionExport citationAdd to favoritesTrack citation ShareShare Give accessShare full text accessShare full-text accessPlease review our Terms and Conditions of Use and check box below to share full-text version of article.I have read and accept the Wiley Online Library Terms and Conditions of UseShareable LinkUse the link below to share a full-text version of this article with your friends and colleagues. Learn more.Copy URL Share a linkShare onFacebookTwitterLinked InRedditWechat Abstract Convective turbulent mass transfer in heated tubes is modeled with internal mass sources resulting from crystallization. The analysis considers the influence of internal mass sources on the concentration distribution, average concentration of colloidal particles and dissolved impurities, and the mass flux at the wall. It was found that if the mass transfer coefficient in the case which considers internal mass sources is defined properly, the Sherwood number and the mass transfer coefficient with internal mass sources are equal to those without internal mass sources. The mass flux and the increase in the wall temperature beneath the iron oxide deposit layer were predicted using two crystallization models. The model predicting crystallization at the wall only is recommended based on predictions of the maximum increase in the wall temperature beneath the deposit layer. © 2000 Scripta Technica, Heat Trans Asian Res, 29(3): 166–180, 2000 Volume29, Issue3May 2000Pages 166-180 RelatedInformation
What problem does this paper attempt to address?