Modified Gradiometer Technique Applied to Double Star (TC-1)

E. Georgescu,H. U. Auster,T. Takada,J. Gloag,H. Eichelberger,K. -H. Fornacon,P. Brown,C. M. Carr,T. L. Zhang
DOI: https://doi.org/10.1016/j.asr.2008.01.014
IF: 2.611
2008-01-01
Advances in Space Research
Abstract:On TC-1 (Tan Ce 1), the equatorial spacecraft of the Double Star mission, a strong spin-synchronized magnetic interference from the solar panels was observed. In-flight correction techniques for spinning spacecraft that are based on minimizing spin tones in the spin-aligned component and in the magnitude of the ambient magnetic field are therefore not possible in this case. However, due to the fortunate situation that the spacecraft carries two flux-gate magnetometers on the same boom (at 0.5m distance from each other), the spacecraft field effects could be removed from the spin-averaged data to achieve 0.2nT relative accuracy, by using a gradiometer technique. Methodology and results are presented. The obtained accuracy allows the use of the data in multi-spacecraft studies together with the Cluster satellites.
What problem does this paper attempt to address?