Simultaneous Determination of Chlorpyrifos and Cypermethrin Residues in Asparagus by SPE-CGC

LIU Cheng-lan,XU Wen-na,LIU Feng-mao,HU Mei-ying,ZHONG Guo-hua,JIANG Shen-ren
DOI: https://doi.org/10.3321/j.issn:1000-2421.2007.01.012
2007-01-01
Abstract:Residues of chlorpyrifos and cypermethrin were determined in asparagus by capillary gas chromatography with electron capture detection(GC-ECD) and an off-line solid phase extraction(SPE) florisil columns.The two pesticides extracted from asparagus by acetonitrile,n-hexane-acetone(V∶V=8∶2,) were used to elute the pesticides from the SPE columns.Chromatographic separation was accomplished with a heated HP-5 quartz column(30 m×320 μm×0.25 μm).The eluent was detected with ECD.Residue levels were determined by an external standard.The limit range of chlorpyrifos and cypermethrin were 0.002 5~0.500 0 mg/L and 0.005~0.250 mg/L,and limit of determination of 0.002 5 mg/kg and 0.005 mg/kg,respectively.The fortified recoveries and relative standard deviation were averaged from 74.0% to 98.3% and 0.6% to 10.8%,respectively.