Experimental Study of Implantable Electrical Stimulation System for Treatment of Rabbits with Acute Sciatic Nerve Injury

王金武,刘晓琳,芮碧宇,黄敏,廖广姗,蒋海涛,戴尅戎
DOI: https://doi.org/10.3977/j.issn.1005-8478.2011.06.18
2011-01-01
Abstract:[Objective]To establish New Zealand white rabbits acute sciatic nerve injury model,validate implantable electrical stimulation system for nerve growth and prevention of muscle atrophy. [Method]Twenty healthy adult New Zealand white rabbits of either sex,average weight 2972±105 g,were chosen to establish acute sciatic nerve injury model.These rabbits were randomly divided into two groups,ten in experimental group,and ten in control group.Experiments were performed on the left side of rabbits,while contralateral side as control side.Electrode was buried proximal and distal to the muscle two weeks after the model had been made.The system was initiated by a magnetic rod.Intermittent electrical stimulation was performed eight hours per day.At two and four weeks,we observed changes in animal behavior,detected sciatic nerve conduction velocity,and measured wet weight of gastrocnemius muscle recovery rate.The animals were sacrificed after electrophysiological testing,specimens experienced histological analysis and molecular biological analysis. [Result]The mental state of experimental group was better than in the control group.Four weeks after surgery,the ipsilateral leg muscles of experimental group had slight atrophy.Sciatic nerve regeneration of the control group was small,these muscles shrank significantly.Tibial nerve and superficial peroneal nerve conduction velocity of experimental group was significantly faster than in the control group(P0.05).Muscle wet weight recovery rate in experimental group was higher than in the control group(P0.05).At four weeks,HE staining test of experimental group showed slightly muscle fiber degeneration,whereas the control group displayed significantly shrinkage of muscle cells,cell gap increased,interstitial inflammatory exudated,and local fibrosis could be found.Both groups expressed nerve growth factor(NGF).However the comparisons between the two groups were significant(P0.05).Electron microscope study:in experimental group,axons were coarse,and myelin structure was normal,in the control group,myelin was degenerated,loosened and bent.RT-PCR of both groups showed expression of β-actin,nNOS mRNA and NGF mRNA.Comparisons between the two groups were significant(P0.05). [Conclusion]Given appropriate stimulation parameters,the implantable electrical stimulation system for rabbit sciatic nerve injury models achieved remarkable results.
What problem does this paper attempt to address?