The application of point-of-care testing for anticoagulation monitoring

韩俊丽,田红燕,吉亚红,刘亚
DOI: https://doi.org/10.3969/j.issn.1671-4695.2012.22.010
2012-01-01
Abstract:Objective To evaluate the significance of point-of-care testing(POCT) in patients receiving treatment of low molecular weight heparin(LMWH) bridging with warfarin or warfarin alone.Methods International normalized ratio(INR) of patients with venous thromboembolism received warfarin combined LMWH or warfarin alone was tested by POCT or laboratory automatic method.Correlation,bias and accuracy of these two testing methods were analyzed.Results In bridging anticoagulation group and warfarin anticoagulation group,the correlation coefficients of these two methods were 0.965 and 0.866(P<0.01) respectively.The bias of bridging anticoagulation group was higher than that of warfarin anticoagulation group.The degrees of accuracy of POCT in two groups were 80.0% and 88.9% respectively.Conclusion In bridging anticoagulation group and warfarin anticoagulation group,the correlation of these two methods is well.The accuracy of POCT is high.The bias of POCT in bridging group is higher than that of warfarin group.
What problem does this paper attempt to address?