A Self-Foaming Solution for Bottom Liquid Removal in Gas Wells

WU Wen-Gang,XIONG Ying,WANG Jun,CHEN Da-Jun
DOI: https://doi.org/10.19346/j.cnki.1000-4092.2007.02.004
2007-01-01
Abstract:An self-foaming solution for removing bottom liquid in poor or watered out natural gas wells and its use are presented.This solution is a gas-generating chemical solution of 1 mol/L NH4Cl and 1 mol/L NaNO2 with a catalyst,a foamer,and a foam stabilizer added.Acetic acid is selected as catalyst through gas generation measuring at 30℃ and pH=3.A chemical kinetic equation for the gas-generating system published else while is recommended for calculating the catalyst,or pH value,need when the gas-generating rate and the bottom temperature are given.In foaming tests,the volume of foam formed from 50 mL gas-generating foaming solution at 30℃ after 60 min stirring at 1000 r/min,the volume of solution foamed,the half-life time,t1/2,of foam,and the volume of foam at t1/2(which is always larger than initial foam volume) are taken as characteristics of foaming capability of the test solution.Through foaming tests,a commercial dodecyl sulfate is chosen as foamer at dosage 0.8% and hydropropyl guar gum—as foam stabilizer at dosage 0.6%.Gas producing well M-144 in central Sichuan district of 2980 m deep and bottom temperature >65℃ was watered out and practically ceased to producing gas;29 m3 of gas-generating foaming solution was injected into the well through the annular space and in result totally 84 m3 accumulated at the well bottom liquid war flown out of the well.After this job finished,this restarted gas production in a rate of 52000 m3/d.