Study on Precision and Accuracy in Method Validation for Quantitative Analysis of Components in Traditional Chinese Medicine

Wang Peng,Song Zong-hua,Li Qing,Guo De-an,Qian Zhong-zhi,Bi Kai-shun
DOI: https://doi.org/10.3969/j.issn.1009-3656.2010.03.011
2010-01-01
Abstract:Objective:To study the specific investigation method of precision,accuracy and range. Methods: For determination of the contents of magnolol and honokilo in cortex magnoliae officinalis by RP-HPLC,in different range,the repeatability and accuracy were evaluated by different methods. Results: For magnolol and honokilo,RSDs of the repeatability were 2.5-5.8% and 2.5-5.7%. The range within ten times. The average recoveries were 95.1-97.7%,with RSDs of 2.2-4.3% and 94.8-97.7%,with RSDs of 2.0-7.5%. Conclusions: RSDs of the repeatability are increased as the range enlarged,and the variance is non-homogeneous between 6 and 9 determined results. RSDs of the recoveries are increased as the range enlarged. When the ratio of added and original amount is 1:1,the error is little relatively. But if recoveries are investigated by changing added amount of reference substance,RSD of the 9 sample results is obviously increased.
What problem does this paper attempt to address?