Percutaneous saphenectomy: a potentially dreadful complication of cutting balloon angioplasty in saphenous vein grafts.

Worawut Tassanawiwat,Giuseppe G L Biondi-Zoccai,Giuseppe Sangiorgi,Ioannis Iakovou,Eleutheria Tsagalou,Gloria Melzi,Lei Ge,Nuccia Morici,Nicola Corvaja,Antonio Colombo
DOI: https://doi.org/10.1016/j.ijcard.2005.01.017
IF: 4.039
2006-01-01
International Journal of Cardiology
Abstract:Vessel perforation is an uncommon but potentially life-threatening complication of percutaneous coronary intervention and is often associated with the use of atheroablative devices. While effective management means are currently available, such as PTFE-covered stent, pericardiocentesis, and perfusion balloon, a timely and skillful approach is of paramount importance to solve this dreadful complication. We hereby describe a case of saphenous vein graft (SVG) perforation occurring after cutting balloon angioplasty for in-stent restenosis. Despite the immediate occurrence of cardiac arrest due to massive extravasation of contrast in the mediastinum with pericardial tamponade, deep catheter intubation enabled the deployment of two PTFE-covered stents and subsequent sealing of the leak with repeated inflation of a perfusion balloon, while hemopericardium was drained by pericardiocentesis. This clinical vignette emphasizes the role of optimal backup in order to deploy life-saving devices and successfully manage life-threatening pericardial tamponade due to SVG rupture.