TREATMENT OF BUTYL XANTHATE WASTEWATER BY SEQUENCING BATCH REACTOR

Zhang Xin,Zhou Hongbo
DOI: https://doi.org/10.16796/j.cnki.1000-3770.2011.01.029
2011-01-01
Abstract:Simulated butyl xanthate wastewater was treated by a sequencing batch reactor(SBR).The effects of mass concentration,aeration rate,feeding mode,settling time on the biodegradation of butyl xanthate were investigated.Experimental results showed that,under the conditions of 8 h completed mixed aeration,100 mg·L-1 influent xanthate concentration,the effluent xanthate concentration was less than 0.4 mg·L-1.At optimum conditions,i.e.12 h running cycle,including 10 min batch wastewater filling,8 h completed mixed aeration,air flow rate of 100 mL·L-1,40 min sludge settling,10 min decantation and 180 min idle period,the influent 100 mg·L-1 xanthate was completely degraded.At the optimum process conditions,maintaining the influent concentration of 100 mg·L-1 constant,aeration time was reduced to 6 h,the SBR runs 3 cycles per day with a full cycle of 8 h,which increases the daily treatment capacity of the SBR reactor.While the effluent xanthate concentration was 0.04 mg·L-1,and the effluent COD concentration is 55 mg·L-1,both meet the emission requirements.
What problem does this paper attempt to address?