Trace determination and electrochemical behaviors of isoniazid on electrochemical pre-treatment glassy carbon electrode

鲁双云,于春梅,姜启玉,顾海鹰,李根喜
DOI: https://doi.org/10.3969/j.issn.1674-7887.2006.01.001
2006-01-01
Abstract:Objective:To study the electrochemical response of isoniazid at electrochemical pretreated glassy carbon electrode(PGCE).Methods:A three-electrode configuration was employed,the working electrode was pretreated glassy carbon electrode(PGCE),the reference and counter electrode was saturated calonael electrode(SCE) and platinum electrode,and cyclic voltammetry(CV) was used to study the electrochemical behavior of isoniazid.Results:Isoniazid on the PGCE generated two irreversible reductive peaks at-0.80V and-0.90V,Its process was a surface adsorption controlled one.In addition,the optimum conditions to detect isoniazid were studied.The peak current at about-0.90V showed a linear dependence with the concentration of isoniazid over the range 1.2×10~(-10) and 1.3×10~(-3)mol/L.The limit of detection of isoniazid was as low as 1.2×10~(-11)mol/L(t_a=40s,S/N=3).Relative standard deviation(RSD) was 4.5% for 1.2×10~(-6) mol/L isoniazid(n=8). The mean percentage recoveries in Britton-Robinson(B-R) buffer and in mimic urine sample containing isoniazid were(101.7±3.8)% and(96.3±3.3)%,respectively.Conclusion:This method,which can be used to detect isoniazid,can be clinically used to detect the drug concentration in the urine of TB patients.