STUDY ON COMPOSITE MEMBRANE/SBR COMBINED SMBR SYSTEM FOR NITROGEN AND PHOSPHORUS REMOVAL EFFICIENCY AND THE CHANGES OF MEMBRANE PERFORMANCE

Rong Zhiyong,Wang Lei,Chen Licheng,Wang Xudong,Lv Yongtao,Zhang Y
DOI: https://doi.org/10.3969/j.issn.1000-3770.2013.03.029
2013-01-01
Abstract:The sequencing batch membrane reactor was constructed by combining of composite membrane and sequencing batch reactor,and the removal effect of COD,NH4+-N,TN,TP and the performance of composite membrane was investigated under different water feed ratio and anoxic mixing/aeration time conditions.The results indicate that the average removal rates of COD、NH4+-N、TN are higher than 90%、95%、70% under different operation conditions,but when the water filling ratio was 33%,TN average removal rate could be reached 79%;The water filling ratio and anoxic mixing/aeration time had large effect on TP removal rate,the TP removal rate could be reached 96% when the water filling ratio was 43% and the mixing time was 2 hours.In the research,the average effluent turbidity was 0.02 NTU.Without do any cleaning on membrane in two months,the trans-membrane pressure kept under 6.0 kPa,and the permeability of membrane ranged from 3.5~4.5 L/(m2.h.kPa),the phenomenon of membrane fracture and serious membrane fouling were not occurred in the SMBR system.