Bond graph model for cardiovascular system
NING Gang-min,Kai Yong Dai,LI Ying-qi,Juan Du,Jie Su,ZHENG Xiao-xiang
2007-01-01
Abstract:Corresponding to human anatomical structure, a bond graph model for cardiovascular circulation system including heart, head and neck circulation, pulmonary circulation, coronary circulation, abdomen circulation and extremity circulation was developed, which comprise of 54 mathematical equations. The blood pressure and blood flow wave on arbitrary site of circulation can be obtained by solving the equations, meanwhile, the stroke volume, cardiac output and eject fraction of heart can be computed. The model achieved the typical physiological parameters such as, systolic/diastolic blood pressure 115/78 mm-Hg, stroke volume 80 mL, cardiac output 5.76 L and eject fraction 64.5%. The simulation results were in agreement with the human physiological experimental data, so that the validity of the model was verified. By adjusting the initial condition parameters of the model, the simulations for pathological features of the cardiovascular system, such as atherosclerosis, hypertension and stenosis in left subclavicle artery were implemented, with the results being consistent with human pathological features. Furthermore, the components of the model are composed of identical but independent structures, so the model is flexible to be extended.