A gold immunochromatographic assay for the detection of Xanthomonas citri pv. citri

Yin Youping,Wu Yujia,Yu Hong,Li Meng,Wang Zhongkang
DOI: https://doi.org/10.3969/j.issn.0529-1542.2012.02.020
2012-01-01
Plant Protection
Abstract:The main aim of this study was to find a gold-immunochromatographic test-strip kit using a colloidal gold-labelled monoclonal antibody,which was developed for the detection of Xanthomonas citri pv.citri(Xcc).Two mouse monoclonal antibodies against Xcc were obtained.One of them(Xcc-Mab2D8) was selected to conjugate with colloidal gold as the detector antibody that was spotted on a conjugate pad,and the other(Xcc-Mab2D6) was used as the capture antibody at the test line(T).Goat anti-mouse IgG antibody was used as the capture antibody at the control line(C).The entire test procedure only took about 10 min without any equipment.The detection limit of the test strip for Xcc concentration as low as 1×103-1×104 cfu/mL scored as positive.We tested 206 samples,and the results were compared with those obtained by qPCR in order to examine the reliability.The two methods showed significant correlation(kappa=95.15%).